Dear Marie,

You might want to share a snippet of your control stream for further help.

You may want to set a lower boundary of 0 for your estimate of F in the $THETA 
block and if you allow inter-individual variability, you may want to do a logit 
transformation of your bioavailability parameter and its variability, to 
constrain the value between 0-1.

Sincerely,
Rob

Van: owner-nmus...@globomaxnm.com <owner-nmus...@globomaxnm.com> namens Marie 
Rajerison <marie.rajeri...@corteriapharma.com>
Datum: dinsdag, 11 maart 2025 om 15:01
Aan: owner-nmus...@globomaxnm.com <owner-nmus...@globomaxnm.com>, 
nmusers@globomaxnm.com <nmusers@globomaxnm.com>
Onderwerp: [NMusers] RE: NONMEM and Bioavailability fraction

Dear NM users

I am running an extravascular pop PK model with dual absorption and got the 
following message from NM:
[cid:image001.png@01DB9294.D8F91820]
Has anyone experienced the same issue and how to fix it?

Thank you in advance for your help


Marie



De informatie in dit bericht is uitsluitend bestemd voor de geadresseerde. Aan 
dit bericht en de bijlagen kunnen geen rechten worden ontleend. Heeft u deze 
e-mail onbedoeld ontvangen? Dan verzoeken wij u het te vernietigen en de 
afzender te informeren. Openbaar maken, kopi?ren en verspreiden van deze e-mail 
of informatie uit deze e-mail is alleen toegestaan met voorafgaande 
schriftelijke toestemming van de afzender. Het Radboudumc staat geregistreerd 
bij de Kamer van Koophandel in het handelsregister onder nummer 80262783.

The content of this message is intended solely for the addressee. No rights can 
be derived from this message or its attachments. If you are not the intended 
recipient, we kindly request you to delete the message and inform the sender. 
It is strictly prohibited to disclose, copy or distribute this email or the 
information inside it, without a written consent from the sender. Radboud 
university medical center is registered with the Dutch Chamber of Commerce 
trade register with number 80262783.

Reply via email to