timoninmaxim commented on a change in pull request #9817:
URL: https://github.com/apache/ignite/pull/9817#discussion_r804927834



##########
File path: 
modules/platforms/dotnet/Apache.Ignite.Core/Impl/Client/ClientSocket.cs
##########
@@ -170,6 +176,29 @@ internal sealed class ClientSocket : IDisposable
 
             _features = Handshake(clientConfiguration, ServerVersion);
 
+            if (_features.HasFeature(ClientBitmaskFeature.Heartbeat) &&
+                clientConfiguration.HeartbeatInterval > TimeSpan.Zero)
+            {
+                _heartbeatInterval = clientConfiguration.HeartbeatInterval;
+
+                var serverIdleTimeout = TimeSpan.FromMilliseconds(
+                    DoOutInOp(ClientOp.GetIdleTimeout, null, r => 
r.Reader.ReadLong()));
+
+                if (_heartbeatInterval > serverIdleTimeout)

Review comment:
       `ClientConnectorConfiguration#getIdleTimeout` can be 0 or negative, it 
means that the idleTimeout is disabled. We should skip the WARN for such cases. 
   
   I don't see such check, but I'm not familiar with .Net so maybe I miss it.




-- 
This is an automated message from the Apache Git Service.
To respond to the message, please log on to GitHub and use the
URL above to go to the specific comment.

To unsubscribe, e-mail: [email protected]

For queries about this service, please contact Infrastructure at:
[email protected]


Reply via email to