timoninmaxim commented on code in PR #12301:
URL: https://github.com/apache/ignite/pull/12301#discussion_r2415989693


##########
modules/core/src/main/java/org/apache/ignite/internal/processors/nodevalidation/OsDiscoveryNodeValidationProcessor.java:
##########
@@ -32,42 +35,76 @@
  * Node validation.
  */
 public class OsDiscoveryNodeValidationProcessor extends GridProcessorAdapter 
implements DiscoveryNodeValidationProcessor {
+    /** Key for the distributed property that holds the rolling upgrade minor 
version check value. */
+    public static final String ROLL_UP_VERSION_CHECK = 
"rolling.upgrade.version.check";
+
+    /**
+     * Distributed property that holds version for rolling upgrade validation.
+     * If value is null {@code null}, rolling upgrade is considered disabled,
+     * and nodes must have the exact same version to join the cluster.
+     */
+    private final AtomicReference<IgniteProductVersion> rollUpVerCheck = new 
AtomicReference<>();
+
     /**
      * @param ctx Kernal context.
      */
     public OsDiscoveryNodeValidationProcessor(GridKernalContext ctx) {
         super(ctx);
+
+        
ctx.internalSubscriptionProcessor().registerDistributedMetastorageListener(new 
DistributedMetastorageLifecycleListener() {
+            @Override public void 
onReadyForRead(ReadableDistributedMetaStorage metastorage) {
+                metastorage.listen(ROLL_UP_VERSION_CHECK::equals, (key, 
oldVal, newVal) -> {
+                    rollUpVerCheck.getAndSet((IgniteProductVersion)newVal);
+
+                    if (newVal == null)
+                        log.warning("Rolling upgrade version check was 
disabled.");
+                });
+            }
+        });
     }
 
     /** {@inheritDoc} */
     @Nullable @Override public IgniteNodeValidationResult 
validateNode(ClusterNode node) {
         ClusterNode locNode = ctx.discovery().localNode();
 
-        // Check version.
         String locBuildVer = locNode.attribute(ATTR_BUILD_VER);
         String rmtBuildVer = node.attribute(ATTR_BUILD_VER);
 
-        if (!Objects.equals(rmtBuildVer, locBuildVer)) {
-            // OS nodes don't support rolling updates.
-            if (!locBuildVer.equals(rmtBuildVer)) {
-                String errMsg = "Local node and remote node have different 
version numbers " +
-                    "(node will not join, Ignite does not support rolling 
updates, " +
-                    "so versions must be exactly the same) " +
-                    "[locBuildVer=" + locBuildVer + ", rmtBuildVer=" + 
rmtBuildVer +
-                    ", locNodeAddrs=" + U.addressesAsString(locNode) +
-                    ", rmtNodeAddrs=" + U.addressesAsString(node) +
-                    ", locNodeId=" + locNode.id() + ", rmtNodeId=" + node.id() 
+ ']';
+        IgniteProductVersion locVer = 
IgniteProductVersion.fromString(locBuildVer);
+        IgniteProductVersion rmtVer = 
IgniteProductVersion.fromString(rmtBuildVer);
 
-                LT.warn(log, errMsg);
+        IgniteProductVersion rollUpVerCheck = this.rollUpVerCheck.get();
 
-                // Always output in debug.
-                if (log.isDebugEnabled())
-                    log.debug(errMsg);
+        if (versionsMatch(rmtVer, locVer) || versionsMatch(rmtVer, 
rollUpVerCheck))

Review Comment:
   We need support only 1 version for joining nodes.



-- 