Xiangdong Huang created IOTDB-636:
-------------------------------------
Summary: Grafana connector does not use correct time unit
Key: IOTDB-636
URL: https://issues.apache.org/jira/browse/IOTDB-636
Project: Apache IoTDB
Issue Type: Bug
Components: grafna
Affects Versions: 0.9.2, 0.9.1, 0.9.0
Reporter: Xiangdong Huang
On rel/0.9, the grafana connector uses the time unit like this:
{code:java}
// code placeholder
@Autowired
public BasicDaoImpl(JdbcTemplate jdbcTemplate) {
this.jdbcTemplate = jdbcTemplate;
Properties properties = new Properties();
String tsPrecision = properties.getProperty("timestamp_precision", "ms");
switch (tsPrecision) {
case "us":
TIMESTAMP_RADIX = 1000;
break;
case "ns":
TIMESTAMP_RADIX = 1000_000;
break;
default:
TIMESTAMP_RADIX = 1;
}
logger.info("Use timestamp precision {}", tsPrecision);
}
{code}
That is to say, it always is "ms"! No configuration file is read!
--
This message was sent by Atlassian Jira
(v8.3.4#803005)