FreeAndNil opened a new issue, #371:
URL: https://github.com/apache/logging-log4net/issues/371
Since 3.2.0 `RemoteSyslogAppender` uses a connected UDP socket. On Linux an
ICMP error for one
datagram (port unreachable, fragmentation needed) is returned by the next
`send()`, which then
transmits nothing. The next record is lost and reported as failed, although
the error belonged to
the one before it.
- The collector port is closed for a while: about every second record is
lost.
- A hop with a smaller MTU than the sending host's interface: a record that
fits the interface but
not the hop is dropped by the router, and the record after it is lost too.
ANT-2026-C2Q2AQZL.
Proposed fix: on a `SocketException`, `RemoteSyslogAppender` sends the same
datagram once more and
reports the first error through the `ErrorHandler`. A failed retry is
counted as lost, as today.
Document `MaxDatagramSize` for paths with a smaller MTU.
--