William San Filippo created MYNEWT-85:
-----------------------------------------

             Summary: Transmit timing for certain BLE transmissions may not 
meet the specification.
                 Key: MYNEWT-85
                 URL: https://issues.apache.org/jira/browse/MYNEWT-85
             Project: Mynewt
          Issue Type: Improvement
          Components: Nimble
    Affects Versions: v0_8_0_beta1
            Reporter: William San Filippo
            Assignee: William San Filippo
            Priority: Critical
             Fix For: v0_8_0_beta2


Although the unplugfest went well in this regard, it could have been because we 
"exaggerated" the amount of clock drift. The current BLE controller code does 
not use an output compare to transmit a BLE frame at a specific time. This 
could cause the transmission to occur outside the BLE specification. The code 
should be modified to use the BLE transceiver HW to enforce more exact 
transmission timing.



--