William San Filippo commented on MYNEWT-277:
--------------------------------------------

Another note on this commit: I modified the default initial connection tx 
octets (from 251 to 27). What this means is that connections will use 27 byte 
sizes unless the host tells it a different initial max tx octets/time.

> Nimble stack not supporting data length extension fully
> -------------------------------------------------------
>
>                 Key: MYNEWT-277
>                 URL: https://issues.apache.org/jira/browse/MYNEWT-277
>             Project: Mynewt
>          Issue Type: Bug
>          Components: Nimble
>    Affects Versions: v0_8_0_beta2
>            Reporter: William San Filippo
>            Assignee: William San Filippo
>             Fix For: v0_8_0_rel
>
>
> The controller was saying it supported data length extension but there were 
> commands that were not supported. We now support the commands except for one 
> caveat: the controller does not honor the Set Data Length Command. It accepts 
> it and should respond properly, but the controller simply ignores the values 
> sent. This is allowed by the specification. At some point in the future we 
> will implement this but for now I will leave it un-implemented



--