Hi all,
I am using NOX Virtual Test Environment
The topology is one OpenFlow switch and two hosts.
Host 1 and host2 continually ping each other.
In monitor component, the aggregate statistics always show 0.
But, if I dump the aggregate statistics on OpenFlow switch, OpenFlow switch did
print aggregate statistics which is non-zero.
My question is why OpenFlow switch always returned 0 for aggregate stats to NOX.
OpenFlow version is 0.8.9~1
NOX version is 0.6.0
On NOX, I issued: ./nox_core -v -i ptcp:2525 pyswitch monitor
On OpenFlow, I issued: ./secchan nl:0 tcp:10.0.2.2:2525 &
===== some NOX log message====
00140|openflow-event|DBG:received stats reply from 002320c72f83
Table stats in from datapath 00:23:20:c7:2f:83
hash2 : 4
linear : 0
00141|openflow-event|DBG:received stats reply from 002320c72f83
Port stats in from datapath 00:23:20:c7:2f:83
0 : 167
1 : 165
00142|openflow-event|DBG:received stats reply from 002320c72f83
Aggregate stats in from datapath 00:23:20:c7:2f:83
{'packet_count': 0L, 'byte_count': 0L, 'flow_count': 0L}
00143|openflow-event|DBG:received stats reply from 002320c72f83
Table stats in from datapath 00:23:20:c7:2f:83
hash2 : 4
linear : 0
00144|openflow-event|DBG:received stats reply from 002320c72f83
Port stats in from datapath 00:23:20:c7:2f:83
0 : 173
1 : 171
00145|openflow-event|DBG:received stats reply from 002320c72f83
Aggregate stats in from datapath 00:23:20:c7:2f:83
{'packet_count': 0L, 'byte_count': 0L, 'flow_count': 0L}
==== dump aggregate statistics from Openflow ======
hda:/cdrom# ./dpctl dump-aggregate nl:0
stats_reply (xid=0xbf8b2f94): flags=none type=2(aggregate)
packet_count=310 byte_count=30380 flow_count=4
hda:/cdrom# ./dpctl dump-aggregate nl:0
stats_reply (xid=0xe7b9f769): flags=none type=2(aggregate)
packet_count=318 byte_count=31164 flow_count=4
Thanks,
MinChi
_______________________________________________
nox-dev mailing list
[email protected]