I am using HP switch with openflow 0.8.9

On Wed, Feb 3, 2010 at 1:02 PM, Ben Pfaff <[email protected]> wrote:
> Normally the OpenFlow reference implementation and Open vSwitch log
> a message when a connection closes.
>
> On Wed, Feb 03, 2010 at 12:59:16PM -0800, Guanyao Huang wrote:
>> Hi
>> What are the logs you were talking about?
>> I saw the following messages. The CPU is only around 30%.
>>
>> 00038|openflow|WARN:stream: send error: Broken pipe
>> 00039|routingMR|ERR:Add flow entry to dp:f7cae4000064 failed with
>> 32:Broken pipe.
>> 00040|openflow|WARN:stream: send error: Bad file descriptor
>> 00041|routingMR|ERR:Send packet to dp:f7cae4000064 failed with 9:Bad
>> file descriptor.
>> 00042|openflow|WARN:stream: send error: Broken pipe
>> 00043|routingMR|ERR:Add flow entry to dp:f7cae40001f4 failed with
>> 32:Broken pipe.
>> 00044|openflow|WARN:stream: send error: Bad file descriptor
>> 00045|routingMR|ERR:Send packet to dp:f7cae40001f4 failed with 9:Bad
>> file descriptor.
>> 00046|openflow|WARN:stream: send error: Broken pipe
>> 00047|routingMR|ERR:Add flow entry to dp:f7cae40000c8 failed with
>> 32:Broken pipe.
>> 00048|openflow|WARN:stream: send error: Bad file descriptor
>> 00049|routingMR|ERR:Send packet to dp:f7cae40000c8 failed with 9:Bad
>> file descriptor.
>> 00050|openflow|WARN:stream: send error: Broken pipe
>> 00051|routingMR|ERR:Add flow entry to dp:f7cae400012c failed with
>> 32:Broken pipe.
>> 00052|openflow|WARN:stream: send error: Bad file descriptor
>> 00053|routingMR|ERR:Send packet to dp:f7cae400012c failed with 9:Bad
>> file descriptor.
>> 00054|openflow|WARN:stream: send error: Broken pipe
>> 00055|routingMR|ERR:Add flow entry to dp:f7cae4000190 failed with
>> 32:Broken pipe.
>> 00056|openflow|WARN:stream: send error: Bad file descriptor
>> 00057|routingMR|ERR:Send packet to dp:f7cae4000190 failed with 9:Bad
>> file descriptor.
>> 00058|openflow|WARN:stream: receive error: Bad file descriptor
>> 00059|nox|WARN:stream: disconnected (Bad file descriptor)
>> 00060|openflow|WARN:stream: receive error: Bad file descriptor
>> 00061|nox|WARN:stream: disconnected (Bad file descriptor)
>> 00062|openflow|WARN:stream: receive error: Bad file descriptor
>> 00063|nox|WARN:stream: disconnected (Bad file descriptor)
>> 00064|openflow|WARN:stream: receive error: Bad file descriptor
>> 00065|nox|WARN:stream: disconnected (Bad file descriptor)
>> 00066|openflow|WARN:stream: receive error: Bad file descriptor
>> 00067|nox|WARN:stream: disconnected (Bad file descriptor)
>> Datapath leave, f7:ca:e4:00:00:64
>> Datapath leave, f7:ca:e4:00:01:f4
>> Datapath leave, f7:ca:e4:00:00:c8
>> Datapath leave, f7:ca:e4:00:01:2c
>> Datapath leave, f7:ca:e4:00:01:90
>>
>>
>> On Tue, Feb 2, 2010 at 9:33 PM, Ben Pfaff <[email protected]> wrote:
>> > On Tue, Feb 02, 2010 at 09:23:52PM -0800, Guanyao Huang wrote:
>> >> I am wondering what is the usual cause for a datapath to proactively
>> >> leaves the network. Is it because it is overburdened or some probe
>> >> messages time-out?
>> >
>> > The easiest way to find out is to look at the logs on the switches.
>> >
>