Oops.. stupid me.  Thanks Martin for correcting me.

Regards
KK

On 22 February 2010 10:35, Martin Casado <[email protected]> wrote:
> I think Muhammed as asking about setting the miss_send_len.
>
> See lib/openflow.cc, search for miss_send_len.
>
>> Hi Muhammad,
>>
>> Which version of OpenFlow are you on?  Selective flow expiration is
>> introduced in OpenFlow v1.0.
>>
>> For OpenFlow v0.8.9, you want to go to
>> src/lib/openflow.cc:
>>  osc.flags =  htons(OFPC_SEND_FLOW_EXP); /* turn on expirations with
>> htons(OFPC_SEND_FLOW_EXP);, turn off with 0 */
>>
>> For OpenFlow v1.0, update
>> src/include/openflow-default.hh:
>>  #define SEND_FLOW_REMOVED true
>>
>> Regards
>> KK
>>
>> On 22 February 2010 10:14, Muhammad Immad Uddin <[email protected]>
>> wrote:
>>
>>>
>>> Hi:
>>>
>>> I know this has been answered earlier as well but I was not able to find
>>> it.
>>> The default behavior of an openflow switch is to forward the header (128
>>> bytes ) of a unmatched packet to the nox controller. I need to force the
>>> openflow switch to send the entire packet to the nox controller. I
>>> remember,
>>> that I need to change one line in one of the source file but can't recall
>>> it. Can anyone share the answer ?
>>>
>>> -Immad
>>>
>>>
>>>
>>>
>>> _______________________________________________
>>> nox-dev mailing list
>>> [email protected]
>>> http://noxrepo.org/mailman/listinfo/nox-dev_noxrepo.org
>>>
>>>
>>>
>>
>> _______________________________________________
>> nox-dev mailing list
>> [email protected]
>> http://noxrepo.org/mailman/listinfo/nox-dev_noxrepo.org
>>
>
>

_______________________________________________
nox-dev mailing list
[email protected]
http://noxrepo.org/mailman/listinfo/nox-dev_noxrepo.org