Hi Manish, Yes, it is possible. What you have to do is that, in the cmu trace file, where energy module is given, just write a condition that if simulator time is 100 secs, then print the trace in the trace file or you can declare a timer over there which will expire as per your desire. Each time when it will expire, it will print the energy values in the trace file.
Hope it helps Regards Mubashir Husain Rehmani Lip6, UPMC, Paris, France www-npa.lip6.fr/~rehmani 2009/1/22 manish chaturvedi <[email protected]> > > Hi, > > I am using energy model in my NS simulation. > > When energy trace is ON, every time the node energy changes, the trace > is generated. This makes trace file size larger. Is there any way to > generate trace of energy status of all nodes at some fixed time or > periodically? > > Please inform or point me to some source of information. > > Thanking you, > Manish > > -- Mubashir Husain Rehmani