On 25 November 2011, Hans Hagen [[email protected]] wrote: > I uploaded a new beta. > ...
> - Hz, dB (actually deci + bel so megabel also works), lx, permille, t,
> k, Da added
Actually decibel is an odd one, a logarithmic unit, so prefixes other than
"deci" are never used. However the implementation is no problem.
> - ad 2: no looking back (would demand an extra correction pass
> elsewhere, maybe some day)
Here I meant just space within the argument to \unit{}. It seems to be
handled correctly now ...
> - ad 8: manipulating the input this way is somewhat beyond the purpose
> of a typesetting system
(Normalisation of numbers and unit prefixes). OK, just seeing where the line
was to be drawn. However, in the code a comment notes the possibility of
automatic conversions to imperial units, which is a step even further, actually.
Personally I don't think it's a good idea. [Or the b-grade movies].
> - ad 9: much will be configureable; see mkiv file for an example of
> defining extra units (\registerunit [units] [point=pt, basepoint=bp]);
Works, although
> - I myself am not going to look in all kind of other tex stuff that lays
> around as it's up to users/usage what is added, given that it fits into
> the model of context; we have the old units modules as starting point
That was a note to self, but any takers ...
I attach a (much shorter) bunch of test cases (source and pdf again).
Thanks,
Robin
units2.tex
Description: units2.tex
units2.pdf
Description: units2.pdf
___________________________________________________________________________________ If your question is of interest to others as well, please add an entry to the Wiki! maillist : [email protected] / http://www.ntg.nl/mailman/listinfo/ntg-context webpage : http://www.pragma-ade.nl / http://tex.aanhet.net archive : http://foundry.supelec.fr/projects/contextrev/ wiki : http://contextgarden.net ___________________________________________________________________________________