Hi,
I am using ntopng and it shows traffic flows as gre, instead of the real
traffic.
Do i have to enable any option?
Greetings


El 1 mar. 2018 20:35, "Simone Mainardi" <maina...@ntop.org> escribió:

> ntopng decapsulates GRE tunnels by default. nprobe needs the following
> option to account for decapsulated traffic:
>
> [--tunnel|-5]                       | Compute flows on tunnelled traffic
> rather than
>                                     | on the external envelope
>
>
> Simone
>
> > On 28 Feb 2018, at 18:28, Rokkhan <rokk...@gmail.com> wrote:
> >
> > Hi,
> >
> > I am sending traffic to one of the ntop interfaces with ERSPAN but
> traffic info shows application as "GRE".
> >
> > ¿Coudl it be configured to inspect the traffic inside the ERSPAN and
> show the real application?
> >
> > Saludos.
> > _______________________________________________
> > Ntop mailing list
> > Ntop@listgateway.unipi.it
> > http://listgateway.unipi.it/mailman/listinfo/ntop
>
> _______________________________________________
> Ntop mailing list
> Ntop@listgateway.unipi.it
> http://listgateway.unipi.it/mailman/listinfo/ntop
_______________________________________________
Ntop mailing list
Ntop@listgateway.unipi.it
http://listgateway.unipi.it/mailman/listinfo/ntop

Reply via email to