Isn't the most interesting information not how old some data is, but how long 
it's overdue (taking into account the peculiarities of this specific hardware)?

I don't now much about actual UPS protocols (except one, of course), but I 
would imagine that a) there are protocols where the UPS pushes data to the 
driver (think interrupts) and b) others where acquiring particular values is 
slow (hardware responds slowly, reading is expensive, value requires averaging).

OTOH, my feeling is that most of this how-long-is-that-data-stale logic belongs 
into upsd, not into each individual driver. (And deciding whether a certain 
data being stale for a certain time is a problem belongs into the application: 
I can live with not knowing when it will be time to replace the battery for 
much longer than with not knowing whether I'm on battery.)

So, what about the driver, at initialization time, telling upsd, for each 
value, what the expected update interval is (with upsd chosing a default for 
the majority of them) and having upsd deal with the rest?
Of course, there should be an additional method for the driver to tell upsd 
that reading a value failed by providing an "undefined" value.

_______________________________________________
Nut-upsdev mailing list
[email protected]
https://alioth-lists.debian.net/cgi-bin/mailman/listinfo/nut-upsdev

Reply via email to