On Mon, Dec 10, 2012 at 1:49 AM, David Woodhouse <[email protected]>wrote:
> Hi Nicu, > > Thanks for this patch. I'd been looking at the OpenUPS, and now that > it's supported by Nut I've bought one. > > It's not fully set up yet; it's got no load attached, and when I plug it > into the box I'm testing Nut on, it has no power supply either. It's > *just* running itself off its (12V 14AH SLA) battery. > > In that situation, it seems to report a battery current of 655.28A, when > I suppose it should be reporting a *negative* current? > Yes indeed it should be reported as negative value. I will check in firmware and make the according changes. Thanks for noticing. Regards, Nicu Pavel
_______________________________________________ Nut-upsdev mailing list [email protected] http://lists.alioth.debian.org/cgi-bin/mailman/listinfo/nut-upsdev