On 3/3/06, Brian Mathis <[EMAIL PROTECTED]> wrote: > battery.voltage: 0.00
Found a bug here. I need a refresher course on floating-point math :-/ > battery.voltage.nominal: 36 > driver.name: tripplite_usb > driver.parameter.port: /dev/hiddev0 > driver.version: 2.1.0 > driver.version.internal : 0.6 > input.voltage: 119 > input.voltage.nominal: 120 > ups.debug.D: 37 37 38 37 0d 00 00 '7787...' > ups.debug.M: 30 30 38 31 0d 00 00 '0081...' > ups.debug.S: 31 34 30 00 5a 30 0d '140.Z0.' Here's the problem: I don't have all the states mapped out yet for ups.debug.S. If you have time to run the battery down on this UPS (preferrably without anything important running on that UPS), I can add the ups.status states for this model. I used to have this written down somewhere, but I can't find it, and I'm not sure when I'll have a chance to run those tests again. You would just need to compile a table with states like "on AC", "on battery", "low battery", "outlets off", etc. with the corresponding ups.debug.S value. Let me know if you need help. -- - Charles Lepple _______________________________________________ Nut-upsuser mailing list Nut-upsuser@lists.alioth.debian.org http://lists.alioth.debian.org/mailman/listinfo/nut-upsuser