Hello,

I am using the om_udp module to feed some messages to a NMS (OpenNMS).
The NMS can receive syslog messages via UDP only. However, as it is
running on the same machine as NXLog, the UDP socket will return OS
error when NXLog tries to send a message while NMS is not running. I
would like to buffer such messages and have them delivered once the
NMS starts up (current implementation discards such messages and logs
an error). I believe om_tcp works in such a way...

Any ideas or plans to solve this in NXLog? Does anybody need this?
There is always the option to add TCP support to the NMS, but it is
quite a big piece of software...