Hi Andreas,

2011/2/3 Andreas WESTIN <andreas.wes...@stericsson.com>:
>> I don't see what that has to do with the device supporting the "PC
>> suite" USB profile, which allows modem access using cdc_phonet.
>
> Currently our platform does not support this.

Well, I know of platforms that do, and have different versions of ISI modems.

>> That is exactly what I meant. This version allows building quirks inside
>> the drivers. An example in pseudo-code:
>>
>> if GIsiVersion.major == 15 and GIsiVersion.minor>= 3:
>>        send( { FOO, value, filler, filler}, callback1 )
>> else:
>>        send( { FOO, value }, callback2 )
>>
>
> Yes, we use a similar solution in gisi, but Rémi pointed out that it would
> be a maintenance problem once there are more versions to support and I tend
> to agree. A solution could be to use a lookup function, but this function
> would need to return something to compare with, an enum perhaps.
> Also are you certain that e.g major == 15 and minor == 25 is still the same
> ISI version, if not then the lookup function could become messy.

The PNS_SUBSCRIBED_RESOURCES_EXTEND_IND is a bit of a special case, as
it requires quirking inside GIsiModem. But see my other response in
that thread.

Cheers,
Aki
_______________________________________________
ofono mailing list
ofono@ofono.org
http://lists.ofono.org/listinfo/ofono