Hi Christopher,

On 08/22/2012 09:24 AM, Christopher Vogl wrote:
Use AT#QSS=2 instead of AT#QSS=1 to get an URC when the SIM is not only
inserted but also when PIN is unlocked and when SMS + phonebook are
ready to be used.

Disable sim state notification in telit_enable() so that we sure get a
notification when we enable it later again. This way we don't have to
query the state the first time. Without this the Telit modem does not
always send an URC when AT#QSS=2 is sent.

Remove sim_inserted_source and sim_inserted_timeout_cb which are not
needed anymore as a consequence.
By the way the 1 second timeout was an ugly hack.

Don't query current SIM status in cfun_enable_cb() as the SIM is
disabled due to prior AT+CFUN=4.

Register '#QSS:' before enabling sim state notifications.

Remove telit_qss_cb() which was used as a callback for querying the
current SIM status.
---
  plugins/telit.c |   96 +++++++++++++++++++-----------------------------------
  1 files changed, 34 insertions(+), 62 deletions(-)


Patch looks good to me overall, however:

cc1: warnings being treated as errors
plugins/telit.c: In function ‘switch_sim_state_status’:
plugins/telit.c:226:4: error: statement with no effect
plugins/telit.c:240:4: error: statement with no effect
plugins/telit.c: At top level:
plugins/telit.c:64:20: error: ‘qss_prefix’ defined but not used

Also, one other thing I'm concerned about is the CFUN=4 usage when we try to set the modem offline. Your comments indicate that the Telit modem resets the SIM when we issue CFUN=4. Going from Online True -> False we don't actually want to reset the SIM. Does CFUN take an extra parameter to turn SIM reset off by any chance?

Regards,
-Denis
_______________________________________________
ofono mailing list
[email protected]
http://lists.ofono.org/listinfo/ofono