You are right, it was my misunderstanding.

What actually happens is that some layer under ofono (maybe the acm-adc
driver of our "old" kernel 2.6.37), detects an error in the communication
and close the port: simply ofono gets an HUP error on the "modem" port and
stop receving any data.
I don't think this issue should be resolved in ofono.

FabioT

_

On Sun, Nov 29, 2015 at 10:47 PM, Denis Kenzior <[email protected]> wrote:

> Hi Fabio,
>
> On 11/24/2015 03:45 AM, Fabio wrote:
>
>> Hello,
>> I'm using ofono 1.16 with some patch to add sms manager to the Ublox
>> driver.
>>
>> Someone could confirm that ofono close the serial port when it receives
>> some unexpected/unprintable character before the "AT+CGMS=<seq>" reply
>> from the modem?
>>
>
> No, oFono does not close serial ports because of garbage.  The syntax will
> generally discard / ignore AT commands that are not properly formatted.
>
>
>> If yes, is possible to discard these characters instead of hanging-up
>> the serial port? Could I have some info about the source I have to patch ?
>>
>>
> Feel free to provide AT command logs to help us better understand what is
> happening.
>
> Regards,
> -Denis
>
> _______________________________________________
> ofono mailing list
> [email protected]
> https://lists.ofono.org/mailman/listinfo/ofono
>



-- 
****************************************************************************************************************************