________________________________
From: [email protected] 
[mailto:[email protected]] On Behalf Of John Russo
Sent: Friday, May 14, 2010 11:46 AM
To: [email protected]
Subject: [ofw] IPoIB in OFED-W
In the current 2.2 branch the IPoIB makefile is written to avoid building for 
versions of Windows later than Server 2003. I assume this is because it is 
written for NDIS 5.x. There is another module called ipoib_cm that builds 
ipoib.sys and appears to be NDIS 6 compatible.  Is this the correct one for 
Windows 2008?  Also, the name infers connected mode which really confuses me.

Yes, your assumptions are mostly correct - both flavors of ipoib build 
ipoib.sys in their respective bin\kernel\ obj*_*_* folders.

ulp\ipoib                      --> NDIS 5    Svr2003 & XP
ulp\ipoib_NDIS6_CM    --> NDIS 6     Vista, Svr 2008, Win7 (Svr2008 R2)

What should we be building to run IPoIB (UD mode) for Windows 2008?   NDIS6 aka 
ulp\ipoib_NDIS6_CM, as NDIS6 is a svr 2008 WHQL requirement.

The _CM indicates this code base 'eventually' will support 'Connected Mode' as 
it's based on the QLogic IPoIB CM work done by Alex E. in days gone by. The 
default mode of operation is UD for now. Once I get some free cycles I will be 
start reviving the CM mode of operation.

stan.


[cid:113063219@14052010-2588]
John F. Russo
Engineering Manager
QLogic Corporation
780 Fifth Avenue
Suite 140
King of Prussia, PA 19406
Direct: 610-233-4866
Fax:      610-233-4777
Cell:     610-246-9903
www.qlogic.com<http://www.qlogic.com>

<<inline: image001.jpg>>

_______________________________________________
ofw mailing list
[email protected]
http://lists.openfabrics.org/cgi-bin/mailman/listinfo/ofw

Reply via email to