Greetings! >-----Original Message----- >From: Fab Tillier [mailto:[email protected]] >Can we make 30000 another reserved value, identical in meaning to 1? This >would provide a smooth upgrade path for current installations, >since the existing registry entry won't be modified. The only 'regression' in >this case is that if you plug in an SRP target on the fabric, it won't >be automatically picked up as it would be before this change (not quite plug >and play, but more plug, rescan, and play).
Making 30000 a 'magic' number concerns me as a potential error source for those who might sometime into the future want to IOC rescan on a 30 second interval; could be confusing behavior. Magic numbers make me nervous, it's bad enough to be using '1'; a slippery slope to be sliding down for sure. In the HCA .inf file, making the 'IocPollInterval' a 'clobber' entry will reset an existing IocPollInterval value to the .inf file supplied (correct) value. Am I correct in this assumption? > >Do we want to have a minimum interval of some sort, to prevent users from >having IOC sweeps fire ever 2 milliseconds? I too was concerned about an IocPollInterval > 1 and < X ?.....; after contemplating the value of 'X', I basically gave up leaving the user to their own foolishness. _______________________________________________ ofw mailing list [email protected] http://lists.openfabrics.org/cgi-bin/mailman/listinfo/ofw