Cycle time distribution too small for Add* operations
-----------------------------------------------------

                 Key: OLIO-81
                 URL: https://issues.apache.org/jira/browse/OLIO-81
             Project: Olio
          Issue Type: Bug
          Components: generic
            Reporter: Shanti Subramanyam
            Assignee: Shanti Subramanyam


Currently, the driver uses a neg. exp. distribution for cycle times with a 5 
second mean and truncates the distribution at 25 seconds. For the Add 
operations, the response times can be quite high - this leads to much smaller 
think times which can cause the requirement for cycle times to fail.

We either need to increase the mean cycle time or truncate at a much larger 
value for these operations.

-- 
This message is automatically generated by JIRA.
-
You can reply to this email to add a comment to the issue online.

Reply via email to