On Sep 3, 2014, at 7:05 AM, David Seira <[email protected]> wrote:

> 
> - Add a flow-control for the aggregation interface:
> 
> flowadm add-flow -l aggr0 -a local_ip=1.2.3.4 flow_aggr0
> 
> After this, if I shutdown one of the interfaces in the switch I loose the 
> connectivity with the server. It seems that the aggregation doesn't forward 
> the traffic to the other interface. 
> 
> Having one of the ports in the switch down, and without connectivity with the 
> server because of the above issue; If I remove the flow (through the console, 
> of course), the server goes online immediately.
> 
> If I add the flow again, the server is innacessible again.

Silly question --> are you adding properties to the flow (priority or maxbw)?  
I don't doubt you've a bug, but I'm curious if it's limited to what is in 
effect a NOP flow, or if it affects a proper flow (where it's enforcing 
something)?

Thanks,
Dan