It was closed by mistake I reopened it.




BR,

Michael Lando
Opensource TL , SDC
AT&T Network Application Development · NetCom
Tel Aviv | Tampa | Atlanta | New Jersey |Chicago
···········································································
Office: +972 (3) 5451487
Mobile: +972 (54) 7833603
e-mail: ml6...@intl.att.com<mailto:ml6...@intl.att.com>

From: feng.yuanx...@zte.com.cn [mailto:feng.yuanx...@zte.com.cn]
Sent: Tuesday, October 31, 2017 3:35 AM
To: Lando,Michael <ml6...@intl.att.com>
Cc: onap-discuss@lists.onap.org; zhang.maope...@zte.com.cn; 
onap-discuss@lists.onap.org; ying.yunl...@zte.com.cn; fu.jin...@zte.com.cn
Subject: The ticket  SDC-533 was closed although the issue was not fixed, would 
you please check it?




    SPGW 2:

      type: org.openecomp.resource.vf.Spgw

      metadata:

        invariantUUID: 488587e7-051a-4fb8-9cd8-44738b3ef88c

        UUID: e524a291-da5c-481f-9059-c0df2e375f73

        customizationUUID: 17c4b1c0-6a5d-4988-b135-683affec6b0e

        version: '0.2'

        name: SPGW

        description: SPGW

        type: VF

        category: Generic

        subcategory: Network Elements

        resourceVendor: zte

        resourceVendorRelease: '1.0'

        resourceVendorModelNumber: ''

      properties:

        nf_naming:

          ecomp_generated_naming: true

        availability_zone_max_count: 1

      requirements:

      - virtualLink:

          capability: tosca.capabilities.nfv.VirtualLinkable

          node: mgmt

      - virtualLink:

          capability: tosca.capabilities.nfv.VirtualLinkable

          node: OM



[cid:image001.png@01D3523C.C0119710]




原始邮件
发件人:冯远兴10034308
收件人: <ml6...@att.com<mailto:ml6...@att.com>>;
抄送人: 
<onap-discuss@lists.onap.org<mailto:onap-discuss@lists.onap.org>>;张茂鹏10030173;
日 期 :2017年10月25日 16:40
主 题 :About the lack of requirements labels in service template using SDC to 
design vEPC service, I've created a ticket SDC-533. If there's anthing I've not 
described clearly, don't hesitate to contact me. Thanks.






https://jira.onap.org/browse/SDC-533<https://urldefense.proofpoint.com/v2/url?u=https-3A__jira.onap.org_browse_SDC-2D533&d=DwMGaQ&c=LFYZ-o9_HUMeMTSQicvjIg&r=RynqW2q8pkELnIhPvHEWeQ&m=TcSgnXVAqUuJ4NGSAwHT-1ktO_VudORz94AMwaPIAic&s=w9OOGaQhBZfZyBukbpptYfINgBeXkZuo6XgFoYfOHuk&e=>



1) Onboard 3rd-party VNF csar files in SDC catalog

2) Import VSP in order to import those 3rd-party VNFs

3) Design a vEPC service using those VNFs.  When I am trying to drag a link 
between SPGW node, which is a VNF, and external virtual link. I could choose 
the requirement of SPGW node as the picture below shows. However, after I 
export this vEPC service template, I can't find the name of the requirement in 
that template. All I've got in service template is just virtual_link while I 
need the exact name of requirements, ToOM instead.

During the period of instantiation, VF-C parses the NSD template and then 
passes the information to VNFM in order to instantiate VNF.

Because of this issue, VF-C can't get the correct names of requirements. 
Therefore VNFM can't get those names too. So VNFM does not know how to attach 
the connection points to the external virtual link.



SPGW:

  metadata:

  ...
  properties:

  ...
  requirements:
  - virtual_link:
    capability: tosca.capabilities.nfv.VirtualLinkable
    node: Control Network
  - virtual_link:
    capability: tosca.capabilities.nfv.VirtualLinkable
    node: Mgmt Network






_______________________________________________
onap-discuss mailing list
onap-discuss@lists.onap.org
https://lists.onap.org/mailman/listinfo/onap-discuss

Reply via email to