Hi, Pam,
From the policy log, it looks like it has both vnf-id and vnf-name:
"generic-vnf.vnf-name": "demovnfVFW110103",
"generic-vnf.model-version-id": "fead6cbe-a374-49ef-9245-4a2bd18d8d7b",
"generic-vnf.model-customization-id":
"977921fb-8e6f-427d-9a0a-2b98bbfdb8c7",
"generic-vnf.nf-function": "",
"generic-vnf.vnf-type": "demoVFW/374fbfc3-b7fd-4f00-9792 0",
"generic-vnf.model-invariant-id": "5f492678-c2e3-4385-a16a-1e781756ce1c",
"generic-vnf.vnf-id": "6e3b0069-a760-4ee4-851d-b80fe2dd8562"
But I didn’t look into the code. If you like we could have a debug session
after the TSC. (Before that, you could also check the deployment at
Integration-SB-00)
Regards,
Helen Chen
From: "DRAGOSH, PAMELA L (PAM)" <[email protected]>
Date: Thursday, November 2, 2017 at 5:28 AM
To: Helen Chen 00725961 <[email protected]>, "HERNANDEZ-HERRERO, JORGE"
<[email protected]>, onap-discuss <[email protected]>
Subject: Re: [onap-discuss] [integration][policy]Need help from Policy now
Helen,
That is not necessarily true. We will look at the logs to be sure but my
suspicion is that the call to A&AI to find the vnf-id for the VPG fails because
the resourceID in the Operational Policy is incorrect. Please recall that the
event comes from a different vnf than what an action will be performed on.
As I have mentioned before, the Operational Policy for vFW that is pushed from
the Policy docker image isn’t up-to-date and we cannot possibly predict what
the resourceID is for the ModifyConfig call. We have been asking for help from
the Integration team for a few weeks on what the value is. What does the
onboarded vFW service look like in the catalog? Are they pre-generated? If not,
then without CLAMP in the picture then the Integration team or Robot scripts
need to re-create the Operational Policy.
Should I open a ticket on the Integration team in order to get this help
prioritized?
Thanks,
Pam
From: Yunxia Chen <[email protected]>
Date: Wednesday, November 1, 2017 at 11:06 PM
To: "HERNANDEZ-HERRERO, JORGE" <[email protected]>, "DRAGOSH, PAMELA L (PAM)"
<[email protected]>, onap-discuss <[email protected]>
Subject: Re: [onap-discuss] [integration][policy]Need help from Policy now
From the following message inside Policy’s log file:
"policyScope": "com",
"policyName": "com.Config_BRMS_Param_BRMSParamvFirewall.EVENT.MANAGER",
"policyVersion": "1",
"notification": "FINAL: FAILURE",
"message": "Target vnf-id could not be found",
"notificationTime": "2017-11-02 03:03:07.643000+00:00",
"history": []
It looks vnf-id, but DCAE gives it vnf-name.
Regards,
Helen Chen
From: <[email protected]> on behalf of Helen Chen 00725961
<[email protected]>
Date: Wednesday, November 1, 2017 at 7:54 PM
To: "HERNANDEZ-HERRERO, JORGE" <[email protected]>, "DRAGOSH, PAM"
<[email protected]>, onap-discuss <[email protected]>
Subject: [onap-discuss] [integration][policy]Need help from Policy now
We are at bridge zoom: 44 6666 8888, testing the closed loop with DCAE and
Multicloud. Need help from Policy team.
Regards,
Helen Chen
_______________________________________________
onap-discuss mailing list
[email protected]
https://lists.onap.org/mailman/listinfo/onap-discuss