Hi William, The VEScollector is also exposed via Nodeport (30235 by default). You can configure the PNF to send events into <k8s node IP address>:30235/eventListener/v5.
Regards, Vijay From: [email protected] <[email protected]> On Behalf Of William Kurkian Sent: Tuesday, June 12, 2018 2:51 PM To: [email protected] Subject: [onap-discuss] MSB - DCAE/VESCollector Hello, Does anyone know how devices external to ONAP, such as a PNF, should access the VES Collector in a Kubernetes installation? One thing I looked at was querying the MSB, but it did not have the VES collector listed, at least in my current installation. I am a few weeks behind, so I don't know if it has been added since. Thanks, William Kurkian
_______________________________________________ onap-discuss mailing list [email protected] https://lists.onap.org/mailman/listinfo/onap-discuss