Hi Jack,

Recently we have moved HV-VES from custom streams definitions to standardized 
DCAE streams (streams_publishes etc.). You are clearly receiving new 
configuration. In that case, I'd say you are using old hv-ves image. Can you 
make sure you are using one of the latest ones, ideally the latest one from 
1.1.0-SNAPSHOT line (sha256: 
26d141d50364b76edeecc6834360605572033675366ac923215eabe5d4960b64). If after 
update the problem remains please post me a sha256 of your image so I can 
proceed with investigation.

BR,
Peter

--
Piotr Jaszczyk
Technical Leader, Software Development
Nokia
Poland, Wrocław, West Gate
________________________________
From: [email protected] <[email protected]> on behalf of 
LUCAS, JOHN (JACK) via Lists.Onap.Org <[email protected]>
Sent: Thursday, April 4, 2019 22:49
To: [email protected]
Subject: [onap-discuss] [dcae] problems deploying hv-ves collector


I’m trying to deploy DCAE (along with some supporting projects—specifically 
consul, dmaap, log, msb, policy, robot, and sdc), and I’m seeing a problem with 
hv-ves collector (version 1.1.0-SNAPSHOT).   I’ve attached the logs.

This deployment has worked in the past, and it’s possible there’s an issue in 
my environment, but I need someone to interpret the logs to tell me what’s 
wrong.



Jack Lucas

AT&T Laboratories

Middletown, NJ 07748 USA

[email protected]



-=-=-=-=-=-=-=-=-=-=-=-