Hi,
We deployed Honolulu version of ONAP without any error fortunately and now we 
want to deploy one scenario for example VFWCL. Documentation is so out-of-date 
and it doesn't help us. In VID Dashboard, based on the documentation, we must 
preload data to sdnc for configuration of VF mudule. For preloading data, we 
use the below API

curl -k -X POST \
https://sdnc.api.simpledemo.onap.org:30267/restconf/operations/GENERIC-RESOURCE-API:vnf-topology-operation
 \
-H 'Accept: application/json' \
-H 'Authorization: Basic 
YWRtaW46S3A4Yko0U1hzek0wV1hsaGFrM2VIbGNzZTJnQXc4NHZhb0dHbUp2VXkyVQ==' \
-H 'Content-Type: application/json' \
-H 'X-FromAppId: API client' \
-H 'X-TransactionId: 0a3f6713-ba96-4971-a6f8-c2da85a3176e' \
-H 'cache-control: no-cache' \
-d ' {
"input": {
"vnf-topology-information": {
"vnf-topology-identifier": {
"service-type": "d22ff55e-b94a-41d7-892c-e284748e456c",
"vnf-name": "VFWCL",
"vnf-type": "VfwclVpkgF40a5456Be46..base_vpkg..module-0",
"generic-vnf-name": "VFWCL",
"generic-vnf-type": "vFWCL_vPKG f40a5456-be46 0"
},
"vnf-assignments": {
"availability-zones": [],
"vnf-networks": [],
"vnf-vms": []
},
"vnf-parameters":
[
{
"vnf-parameter-name": "image_name",
"vnf-parameter-value": "ubuntu-20"
},
{
"vnf-parameter-name": "flavor_name",
"vnf-parameter-value": "m1.medium"
},
{
"vnf-parameter-name": "public_net_id",
"vnf-parameter-value": "adb9c5ec-5444-4b7b-ba57-cddad5c68fb2"
},
{
"vnf-parameter-name": "unprotected_private_net_id",
"vnf-parameter-value": "b762ce61-1406-494d-817d-71cc0ca0fd08"
},
{
"vnf-parameter-name": "unprotected_private_subnet_id",
"vnf-parameter-value": "cafc0dc4-3a6d-489a-bf2e-898ec3402d7b"
},
{
"vnf-parameter-name": "protected_private_net_id",
"vnf-parameter-value": "ea71fc84-072f-49d6-83b0-423520cc8f7d"
},
{
"vnf-parameter-name": "protected_private_subnet_id",
"vnf-parameter-value": "zdfw1fwl01_protected_sub"
},
{
"vnf-parameter-name": "onap_private_net_id",
"vnf-parameter-value": "e4c257f1-084d-48dd-897e-f6ded60f18a7"
},
{
"vnf-parameter-name": "onap_private_subnet_id",
"vnf-parameter-value": "c7d47086-6ddf-4243-921c-e886fa5874f1"
},
{
"vnf-parameter-name": "unprotected_private_net_cidr",
"vnf-parameter-value": "10.10.0.0/24"
},
{
"vnf-parameter-name": "protected_private_net_cidr",
"vnf-parameter-value": "10.20.20.0/24"
},
{
"vnf-parameter-name": "onap_private_net_cidr",
"vnf-parameter-value": "10.10.10.0/24"
},
{
"vnf-parameter-name": "vfw_private_ip_0",
"vnf-parameter-value": "10.20.20.10"
},
{
"vnf-parameter-name": "vpg_private_ip_0",
"vnf-parameter-value": "10.20.20.11"
},
{
"vnf-parameter-name": "vpg_private_ip_1",
"vnf-parameter-value": "10.10.10.11"
},
{
"vnf-parameter-name": "vsn_private_ip_0",
"vnf-parameter-value": "10.20.20.13"
},
{
"vnf-parameter-name": "vpg_name_0",
"vnf-parameter-value": "VFWCL"
},
{
"vnf-parameter-name": "vnf_id",
"vnf-parameter-value": "vPacketGen_demo_app"
},
{
"vnf-parameter-name": "vf_module_id",
"vnf-parameter-value": "vPacketGen"
},
{
"vnf-parameter-name": "repo_url_blob",
"vnf-parameter-value": "https://nexus.onap.org/content/sites/raw";
},
{
"vnf-parameter-name": "repo_url_artifacts",
"vnf-parameter-value": "https://nexus.onap.org/content/repositories/releases";
},
{
"vnf-parameter-name": "demo_artifacts_version",
"vnf-parameter-value": "1.2.1"
},
{
"vnf-parameter-name": "install_script_version",
"vnf-parameter-value": "1.2.1"
},
{
"vnf-parameter-name": "key_name",
"vnf-parameter-value": "heat_key"
},
{
"vnf-parameter-name": "pub_key",
"vnf-parameter-value": "ssh-rsa 
AAAAB3NzaC1yc2EAAAADAQABAAABAQC.....JYa9yOcfdo/6EX3Gzw8tGOJvskkK8/I1z1Hg7wW2Yy0GFYzzK9tRsyrYX1WVXHvsvBvYskIW+XwiYHlHubAZ1dA/j3vWw9NSY2D0BU4snQLfEOIiDejzNvPy6mWrJAXPqEWZ7dNhqU+3jj3zXHuSKP476ayKWAy0QTdYLhfawhJPR
 Generated-by-Nova"
},
{
"vnf-parameter-name": "cloud_env",
"vnf-parameter-value": "openstack"
}

]
},
"request-information": {
"request-id": "robot12",
"order-version": "1",
"notification-url": "openecomp.org",
"order-number": "1",
"request-action": "PreloadVNFRequest"
},
"sdnc-request-header": {
"svc-request-id": "robot12",
"svc-notification-url": 
"http:\/\/openecomp.org:8080\/adapters\/rest\/SDNCNotify",
"svc-action": "reserve"
}
}
}'

but we got this error:

{"errors":{"error":[{"error-type":"protocol","error-tag":"malformed-message","error-message":"Error
 parsing input: Schema node with name vnf-topology-information was not found 
under 
(org:onap:sdnc:northbound:generic-resource?revision=2017-08-24)input.","error-info":"Schema
 node with name vnf-topology-information was not found under 
(org:onap:sdnc:northbound:generic-resource?revision=2017-08-24)input."}]}}

We search alot but we didn't find anything. Please help us to identify the root 
cause of problem.

Thanks in advanced


-=-=-=-=-=-=-=-=-=-=-=-
Links: You receive all messages sent to this group.
View/Reply Online (#23641): https://lists.onap.org/g/onap-discuss/message/23641
Mute This Topic: https://lists.onap.org/mt/87004532/21656
Mute #sdnc:https://lists.onap.org/g/onap-discuss/mutehashtag/sdnc
Group Owner: [email protected]
Unsubscribe: https://lists.onap.org/g/onap-discuss/unsub 
[[email protected]]
-=-=-=-=-=-=-=-=-=-=-=-


Reply via email to