I'm not sure if you have seen this, but there is a guide from Dell on
this subject:

http://www.support.dell.com/support/edocs/software/appora10/lin_x86_64/multlang/EELinux_storage_4_1.pdf

Also I would suggest the following changes in multipath.conf for RHEL5

 device {
         vendor "EQLOGIC"
         product "100E-00"
         getuid_callout "/sbin/scsi_id -g -u -s /block/%n"
         hardware_handler "0"
         path_selector "round-robin 0"
         path_grouping_policy multibus
         failback immediate
         features "1 queue_if_no_path"
         path_checker tur
         rr_min_io 10
         rr_weight uniform
 }