Can anybody help me figure out what happened here? How can an Rx call failure during a volume dump result in the volume-being-dumped becoming unattachable?
- a VolserLog:Tue Jun 26 03:34:58 2007 1 Volser: DumpVolume: Rx call failed during dump, error -01 VolserLog:Tue Jun 26 03:36:07 2007 trans 67182 on volume 536873501 is older than 300 seconds VolserLog:Tue Jun 26 03:36:37 2007 trans 67182 on volume 536873501 is older than 330 seconds VolserLog:Tue Jun 26 03:37:07 2007 trans 67182 on volume 536873501 is older than 360 seconds VolserLog:Tue Jun 26 03:37:37 2007 trans 67182 on volume 536873501 is older than 390 seconds VolserLog:Tue Jun 26 03:37:58 2007 1 Volser: DumpVolume: Rx call failed during dump, error -01 VolserLog:Tue Jun 26 03:39:14 2007 VAttachVolume: Error reading namei vol header /vicepa/V0536872025.vol; error=101 VolserLog:Tue Jun 26 03:39:14 2007 VAttachVolume: Error attaching volume /vicepa/V0536872025.vol; volume needs salvage; error=101 -- PGP/GPG: 5C9F F366 C9CF 2145 E770 B1B8 EFB1 462D A146 C380 _______________________________________________ OpenAFS-info mailing list [email protected] https://lists.openafs.org/mailman/listinfo/openafs-info