Not enough information. Create and attach a hb_report for the shutdown case.
On Tue, Mar 8, 2011 at 8:08 PM, Beau Sapach <[email protected]> wrote: > Hello everyone, > > I’ve got a 2-node cluster that exposes iSCSI targets backed by LVM volumes > on top of a DRBD device. For the most part I’ve got everything working as > I’d like. Manually moving resources works just fine, either using ‘move’ or > by putting a node on standby. Shutting down the corosync service on one > node is another story though. I have an order constraint in place to make > iscsi-scst shutdown before stopping the LVM volume group but in the logs I > see this: > > Mar 08 11:43:07 iscsitest2 crmd: [20755]: info: process_lrm_event: LRM > operation clusterip_stop_0 (call=72, rc=0, cib-update=91, confirmed=true) ok > Mar 08 11:43:07 iscsitest2 crmd: [20755]: info: do_lrm_rsc_op: Performing > key=88:89:0:1effe13b-3093-4bf7-ae29-f764aaf22933 op=iscsi_target_stop_0 ) > Mar 08 11:43:07 iscsitest2 lrmd: [20752]: info: rsc:iscsi_target:73: stop > Mar 08 11:43:07 iscsitest2 lrmd: [24805]: WARN: For LSB init script, no > additional parameters are needed. > Mar 08 11:43:07 iscsitest2 lrmd: [20752]: info: RA output: > (iscsi_target:stop:stdout) Stopping iSCSI-SCST target service: > Mar 08 11:43:07 iscsitest2 lrmd: [20752]: info: RA output: > (iscsi_target:stop:stdout) succeeded. > Mar 08 11:43:07 iscsitest2 lrmd: [20752]: info: RA output: > (iscsi_target:stop:stdout) Removing iSCSI-SCST target modules: > Mar 08 11:43:07 iscsitest2 crmd: [20755]: info: do_lrm_rsc_op: Performing > key=51:89:0:1effe13b-3093-4bf7-ae29-f764aaf22933 op=drbd_lvm_stor:1_demote_0 > ) > Mar 08 11:43:07 iscsitest2 lrmd: [20752]: info: rsc:drbd_lvm_stor:1:74: > demote > Mar 08 11:43:07 iscsitest2 lrmd: [20752]: info: RA output: > (drbd_lvm_stor:1:demote:stderr) 1: State change failed: (-12) Device is held > open by someone > > The first line is fine, the iSCSI target IP should be shutdown first, then > the target service and its modules are stopped/unloaded. Next though I see > corosync trying to demote the DRBD device that sits ‘under’ the LVM volume > group, BEFORE it shuts down LVM… why are these things being done out of > order? Based on my constraint corosync should: > > > Shutdown iscsi IP > Shutdown iscsi-scst > Shutdown LVM > Demote drbd device > > > The order constraint in my configuration looks like this: > > order san_startup inf: ms_drbd_lvm_stor:promote lvm_vg0 iscsi_target > clusterip > > Lastly, I see, near the end of the log: > > Mar 08 11:43:11 iscsitest2 lrmd: [20752]: info: RA output: > (drbd_lvm_stor:1:demote:stdout) > > Which, to me, looks like an incomplete line, followed by a number of attrd, > crmd, stonithd & cib ERROR messages indicating that the connection to the > OpenAIS service has been lost. I suppose this means that corosync doesn’t > wait for proper resource migration before it shuts down which seems very > strange to me. Unless I’m missing something here, has anyone else run into > anything like this? > > Beau > > > _______________________________________________ > Openais mailing list > [email protected] > https://lists.linux-foundation.org/mailman/listinfo/openais > _______________________________________________ Openais mailing list [email protected] https://lists.linux-foundation.org/mailman/listinfo/openais