manpage needs changing too regards -steve
On 07/15/2011 08:13 AM, Jan Friesse wrote: > Previous default (50) was too low for most modern switch hardware. This > may trigger abort because the aru doesn't increase for 50 token > rotations combined with a defect in how failed to recv conditions are > handled. By increasing this tunable, the condition should no longer > trigger the errant code. > > Signed-off-by: Jan Friesse <[email protected]> > --- > exec/totemconfig.c | 2 +- > 1 files changed, 1 insertions(+), 1 deletions(-) > > diff --git a/exec/totemconfig.c b/exec/totemconfig.c > index 5135672..80ca182 100644 > --- a/exec/totemconfig.c > +++ b/exec/totemconfig.c > @@ -73,7 +73,7 @@ > #define JOIN_TIMEOUT 50 > #define MERGE_TIMEOUT 200 > #define DOWNCHECK_TIMEOUT 1000 > -#define FAIL_TO_RECV_CONST 50 > +#define FAIL_TO_RECV_CONST 2500 > #define SEQNO_UNCHANGED_CONST 30 > #define MINIMUM_TIMEOUT (int)(1000/HZ)*3 > #define MAX_NETWORK_DELAY 50 _______________________________________________ Openais mailing list [email protected] https://lists.linux-foundation.org/mailman/listinfo/openais