On Tue, Oct 09, 2012 at 12:56:54PM +0200, jolly wrote:
> hi holger,
> 
> since all SI (5 and 6) are equal for all TRX of BTS, the si_valid should
> stay part of BTS structure. resetting it will break the static
> assignment feature via VTY.

what is the reason to re-generate some of the SI when the n-th trx is up?
Shouldn't we generate the SI once and then based on the TRX decide which
one (gen_si) to send to the BTS?


> the first part of my patch ensures that only generated SI are set to
> valid. other static SI may be valid or not, as specified via VTY.

patch looks fine (didn't review and I don't know much about the static
SI generation). Please commit.

Reply via email to