On Thu, Feb 07, 2013 at 11:58:14AM +0100, jolly wrote:

> this patch fixes the IMMIDIATE ASSIGNMENT REJECT message of OpenBSC. it
> is tested and works.

what and how was it tested? But yes, it is pretty obvious that the reject
is message was wrong. thanks for spotting it.


> A default T3122 timer value of 10 is defined by default now. If set to 0,
> the reject message will not be sent. Note that when using existing configs
> with T3122 value set to 0.

What I have done in the past is to update the example configuration files.
Could you please do that?

Reply via email to