On Thu, Feb 07, 2013 at 11:58:14AM +0100, jolly wrote: > this patch fixes the IMMIDIATE ASSIGNMENT REJECT message of OpenBSC. it > is tested and works.
what and how was it tested? But yes, it is pretty obvious that the reject is message was wrong. thanks for spotting it. > A default T3122 timer value of 10 is defined by default now. If set to 0, > the reject message will not be sent. Note that when using existing configs > with T3122 value set to 0. What I have done in the past is to update the example configuration files. Could you please do that?