On Wed, Nov 04, 2015 at 11:32:59AM +0500, Amber and Sarosh wrote: > Hi,Can someone inform us if the VTY configuration commands to change > parameters e.g. cell id, location area code, MS power etc. that are > run on OpenBSC VTY telnet interface take effect on next restart of > the OpenBSC session or during the same session? If former is the case, > is there any way to dynamically change Cell ID, LAC, MS TX power etc > i.e. without restarting the OpenBSC session?
* you don't need to restart openbsc to change any parameter * some parameters (almost all under the bts/trx/ts nodes) are communicated via A-bis OML at BTS connection time. Those parameters are not becoming effective until the BTS re-connects and thus goes throug OML initialization. There is a vty command that you can use to drop the a-bis OML connection for a specific BTS. * other parameters (affecting OpenBSC behavior directly) become effectively immediately. -- - Harald Welte <[email protected]> http://laforge.gnumonks.org/ ============================================================================ "Privacy in residential applications is a desirable marketing option." (ETSI EN 300 175-7 Ch. A6)