> On 20 Sep 2016, at 12:35, Dhananjay kumar <[email protected]> wrote: >
Dear Dhananjay, > While ruining osmo-bts and osmo-trx via VTY we tried to change parameter > like Band ,ARFCN MS max power. > > We observed that once ARFCN is changed on VTY TRX does not switch to new > ARFCN. > Same behavior has been observed with Band and MS-Max-Power and RF-Locked 0/1 > parameter. > > Request someone who is running osmo-stack has controlled network ,please > reply or any document/pointer is appreciated. few VTY parameters are applied right-away. We have: * Some parameters are applied on restart only (e.g. channel combination of a BTS) * Some on new BTS connection (e.g. arfcn) * Some on next MS connection It would be nice if you could help us by first documenting when/which change is applied and maybe help on creating a concept for consistent handling. E.g. a lot of other equipment requires to bring a system into a "lock" state, do the modification, unlock (the time things will be applied). holger