> On 20 Sep 2016, at 12:35, Dhananjay kumar <[email protected]> wrote:
> 

Dear Dhananjay,

> While ruining  osmo-bts and osmo-trx via VTY we tried to change parameter 
> like Band ,ARFCN MS max power.
> 
> We observed that once ARFCN is changed on VTY TRX does not switch to new 
> ARFCN. 
> Same behavior has been observed with Band and MS-Max-Power and RF-Locked 0/1 
> parameter.
> 
> Request someone who is running osmo-stack has controlled network ,please 
> reply or any document/pointer is appreciated. 


few VTY parameters are applied right-away. We have:

* Some parameters are applied on restart only (e.g. channel combination of a 
BTS)
* Some on new BTS connection (e.g. arfcn)
* Some on next MS connection

It would be nice if you could help us by first documenting when/which change is 
applied and maybe help on creating a concept for consistent handling. E.g. a 
lot of other equipment requires to bring a system into a "lock" state, do the 
modification, unlock (the time things will be applied).


holger

Reply via email to