> On 07 Dec 2016, at 19:03, Kristian Martens <[email protected]> wrote:
>
> Thank you, yes, I can see
Hi!
> Thu Jan 1 03:14:10 1970 <000a> osmo_bsc_bssap.c:398 Rx MSC UDT BSSMAP PAGING
> Thu Jan 1 03:14:10 1970 <000a> osmo_bsc_bssap.c:149 Unsupported Cell
> Identifier List: 00 62 f2 97 00 01 00 00
>
> How can this list be setup in the BSC?
So far none of my customers used that paging mode and before implementing
something that might or might not be correct, I decided to put an error in
it so it can be added in the future.
a.) Add mode for it and send a patch
b.) Ask someone to implement this mode?
c.) Switch to the one "supported"
have a nice evening
holger