Hi Neels, On 4/12/19 7:18 AM, Neels Hofmeyr wrote: > I can only suspect that somewhere the value range is stripped??
I was able to reproduce the issue, and indeed one byte does get stripped off - that's why we end up with 0 as local reference. I've created an issue here: https://osmocom.org/issues/3921 Regards, Oliver -- - Oliver Smith <[email protected]> https://www.sysmocom.de/ ======================================================================= * sysmocom - systems for mobile communications GmbH * Alt-Moabit 93 * 10559 Berlin, Germany * Sitz / Registered office: Berlin, HRB 134158 B * Geschaeftsfuehrer / Managing Director: Harald Welte
