A small typo there..
" On the Iuh side we have Spidercloud wireless Services Node"
Right should be right😊
/Sjur

-----Original Message-----
From: Sjur Thomas Lien <[email protected]>
Sent: Tuesday, April 12, 2022 2:32 PM
To: Pau Espin Pedrol <[email protected]>; [email protected]
Subject: RE: Osmo MGW problem with real Ericsson MGW

Hi,

Thanks for feedback.
No, I mean Ericsson MGW.
On the Iuh side we have Spidercloud wires Services Node.
The RTP link to Iuh is OK, problem is Osmo MGW - Ericsson Mgw.

But Ok, I'll get in contact with Sysmocom.

Regards,
/Sjur


-----Original Message-----
From: Pau Espin Pedrol <[email protected]>
Sent: Tuesday, April 12, 2022 12:45 PM
To: Sjur Thomas Lien <[email protected]>; [email protected]
Subject: Re: Osmo MGW problem with real Ericsson MGW

Hi,

I guess you mean Ericsson HNB, not Ericcson MGW as you wrote in the email topic.

this is the problem:

On 4/12/22 12:24, Sjur Thomas Lien wrote:
> <0019> iuup.c:537 IuUP(C6A09234)[0x562a59d9c600]{Initialisation}:
> Initialization: Unexpected RFCI 1 at position 0 received

Our IuUP implementation expects RFCI num X to be at position X of the array 
(starting from 0). This is a limitation of the current implementation, which 
worked well with nano3g HNB so far.

see libosmocore/src/gsm/iuup.c

Patches to improve IuUP support are welcome. Otherwise, if you need someone to 
invest some hours into improving this part of the code or any integration work 
in general, I kindly remind you that you can contact sysmocom for commercial 
support on this kind of topics.

Regards,
Pau

--
- Pau Espin Pedrol <[email protected]>         
https://eur02.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww.sysmocom.de%2F&amp;data=04%7C01%7Csjur.lien%40telenormaritime.com%7C2ed646778787496f5eb108da1c807dc3%7C579dbaf09d0842198b3c801076d56f15%7C1%7C0%7C637853635636416474%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C3000&amp;sdata=Z%2FuYsUlM2R53DIhSWSs8Dx5EuwMy%2BEb2%2BkxnFcfpe8c%3D&amp;reserved=0
=======================================================================
* sysmocom - systems for mobile communications GmbH
* Alt-Moabit 93
* 10559 Berlin, Germany
* Sitz / Registered office: Berlin, HRB 134158 B
* Geschaeftsfuehrer / Managing Director: Harald Welte

Internal

Internal

Internal

Reply via email to