Hi Mychaela,

On Thu, Apr 21, 2022 at 10:51:13PM -0800, Mychaela Falconia wrote:
> I just made another run and got the pcap:
> 
> https://www.freecalypso.org/members/falcon/osmo-cni/session2.pcap

excellent.

What can be seen is that 
* Frame 2801: CHAN RQD (RACH) with Access Delay = 0
* Frame 2840: CHAN ACT (SDCCH) with TA = 0
* Frame 3035: MEAS RES with TA=0, Timing Offset = 63
* Frame 3142: MEAS RES with TA=0, Timing Offset = 191
* Frame 3150: MEAS RES with TA=0, Timing Offset = 195
* Frame 3248: MEAS RES with TA=8, Timing Offset = 198
...
* Frame 5218: MEAS RES Actual TA=0, Timing Offset 12
* Frame 5312: MEAS RES Actual TA=8, Timing Offset 11
* Frame 5407: MEAS RES Actual TA=8, Timing Offset 1
* Frame 5689: CHAN ACT (TCH) with TA=8

So somehow your MS is moving extremely fast away from the cell, reporting 
enormous
timing offset and causing a high TA to be used on the TCH. And despite that 
high TA,
the MS still reports a timing offset of 63.

I suspect some serious problem in the TA control loop either on MS or BTS side.

-- 
- Harald Welte <[email protected]>            http://laforge.gnumonks.org/
============================================================================
"Privacy in residential applications is a desirable marketing option."
                                                  (ETSI EN 300 175-7 Ch. A6)