Hi Jean-Marc,

On 11/30/23 10:17, [email protected] wrote:
Hi
Many many thanks to you, Pau & Neels

Sorry for my unclear questions.

The fact is we want to test to integrate Osmocom with some Ericsson nodes:
MSC, MGW, SGSN

It should be indeed possible to interop with them, it's been done already.


If we understand well, concerning the link between BSC and MSC, an OSMO-STP
is the best solution (link SCCP M3UA / declaration of AS, ASP, RK, CP, ...)

That's the usual approach yes. Whatever should be fine as long as the Ericsson peer is configured as ASP or SG.


Concerning the CP and UP of the MGW Ericsson and MSC Ericsson, sorry for my
misunderstanding, what do you advice us ?
if we look to the schema, do we need an Osmocom-mgw ? We presume Yes
If Yes, Is it possible to just have one Osmocom-mgw hosted on the
Osmocom-bsc ?

You definetly need an osmo-mgw co-located/used by osmo-bsc.

In this case, There will be RTP traffic between Osmocom-bts and Osmocom-mgw
(hosted on Osmocom-bsc)
And there will be RTP traffic between Osmocom-mgw (hosted on Osmocom-bsc)
and mgw Ericsson.
And there will be MGCP traffic between Osmocom-mgw (hosted on Osmocom-bsc)
and Osmocom-bsc.

Correct.

In case you are interested, let me remind you that "sysmocom - systems for mobile communications GmbH" (https://sysmocom.de) offers commercial support contracts, in case you require further support for your specific needs or help with integrating/interoperating against other vendors or implementing/fixing any features.

Regards,
Pau

--