Dear experts,
We are trying to connect an osmocom platform to an Ericsson platform, and are 
trying to make funtional 2G.
We use a VM for OSMO-BSC, a VM for OSMO-BTS-TRX + OSMO-PCU, and a Raspberry PI 
(trx-lms) 
Concerning the Gb, we connected the OSMO-PCU to an MKX Ericsson, and we have an 
error at the NS setup step.

The communication between the SGSN Ericsson and the OSMO-PCU seems ok (IP / 
routing OK)
We hope that the Ericsson MKX SGSN is well configured.

We can see some packets:  OSMO-PCU ---> SGSN    :    NS_RESET, Cause: P&M 
intervention, NS VCI: 0x1388, NSEI: 5000
and a response from the SGSN:    NS_STATUS, Cause PROTOCOL ERROR - unspecified.

What could be the problem ? timers ? ns-vci, nsvc 1, encapsulation,...
Did someone test this: OSMOCOM with an ERICSSON SGSN ?

One point is that the nsvci is only defined on the BSC (not on the SGSN)

Many thanks in advance,
Best regards
Hoping that you could help us

Jean-Marc
-----------------------
BSC CONFIGURATION
-----------------------
bts 0
  type osmo-bts
  description LimeSDR Based BTS
  band GSM900
  cell_identity 41023
  location_area_code 390
  base_station_id_code 63
  ms max power 15
  cell reselection hysteresis 4
  rxlev access min 0
  radio-link-timeout 32
  channel allocator mode chan-req ascending
  channel allocator mode assignment ascending
  channel allocator mode handover ascending
  channel allocator mode vgcs-vbs ascending
  rach tx integer 9
  rach max transmission 7
  rach max-delay 63
  channel-description attach 1
  channel-description bs-pa-mfrms 5
  channel-description bs-ag-blks-res 1
  no nch-position
  no access-control-class-ramping
  early-classmark-sending forbidden
  early-classmark-sending-3g allowed
  ipa unit-id 901 0
  oml ipa stream-id 255 line 0
  neighbor-list mode automatic
  codec-support fr
  gprs ns timer tns-block 3
  gprs ns timer tns-block-retries 3
  gprs ns timer tns-reset 3
  gprs ns timer tns-reset-retries 3
  gprs ns timer tns-test 30
  gprs ns timer tns-alive 3
  gprs ns timer tns-alive-retries 10
  gprs nsei 5000
  gprs nsvc 0 nsvci 5000
  gprs nsvc 0 local udp port 23001
  gprs nsvc 0 remote ip 172.20.168.220
  gprs nsvc 0 remote udp port 2157
...
-----------------------
PCU CONFIGURATION
-----------------------
ns
 timer tns-block 3
 timer tns-block-retries 3
 timer tns-reset 3
 timer tns-reset-retries 3
 timer tns-test 30
 timer tns-alive 3
 timer tns-alive-retries 10
 timer tsns-prov 3
 timer tsns-size-retries 3
 timer tsns-config-retries 3
 timer tsns-procedures-retries 3
pcu
 flow-control-interval 10
 cs 2
 cs max 4
 cs threshold 10 33
 cs downgrade-threshold 200
 cs link-quality-ranges cs1 6 cs2 5 8 cs3 7 13 cs4 12
 mcs link-quality-ranges mcs1 6 mcs2 5 8 mcs3 7 13 mcs4 12 15 mcs5 14 17 mcs6 
16 18 mcs7 17 20 mcs8 19 24 mcs9 23
 mcs max 9
 window-size 64 0
 queue idle-ack-delay 10
 queue codel