Hello,

I have change the format of my files from the general binary format to binary native file format (dx) because I wanted the connections to be inside the files and not calculated. I am surprised not to be able to extract the different fields (pressure, temperature...). The Import module is following by Select and Selector ones and I have the following error message : ERROR: SELECTOR: Bad parameter: object must be a group or string list. I have understood that Import module take by default the last object of the .dx file. It should contains the different
components
Any help is welcome

Thanks
S. Glockner

PS:

Here is my header file

object 1 class array type float rank 1 shape  2 items     81 msb binary
data file conv2d_000006.bin ,4
attribute "dep" string "positions"

object 2 class gridconnections counts 9 9

object 3 class array type float rank 0 items     81 msb binary
data file conv2d_000006.bin,   660
attribute "dep" string "positions"

object 4 class array type float rank 0 items     81 msb binary
data file conv2d_000006.bin,   992
attribute "dep" string "positions"

object "irreg positions irreg connections binary files" class field
component "positions" value 1
component "connections" value 2
component "pression" value  3
component "temperature" value  4

end

--
Stéphane Glockner Laboratoire MASTER-ENSCPB
16,avenue Pey Berland
33607 Pessac Cedex
Tel : 05 40 00 66 82  Fax : 05 40 00 66 68
Email : mailto:[EMAIL PROTECTED]

Reply via email to