On 09/21/2018 11:05 PM, Burton, Ross wrote:
Is there a good reason why shell=True is used in the first place?
Just change the cmd to a list, stop passing shell=True, and you don't
need to dance around process groups.

Thanks for your suggestion. I'll send out V2 if all things go well with my local testings.

Best Regards,
Chen Qi

Ross
On Fri, 21 Sep 2018 at 03:30, Chen Qi <[email protected]> wrote:
The current handling of SIGTERM is incorrect as the process pid returned
by Popen call with shell setting to True is actualy the shell instead of
the qemu binary. So fix to send SIGTERM to the process group of runqemu.
This ensures that all processes in the same process group, including the
shell and the qemu process, will receive SIGTERM.

Also, as we install a SIGTERM handler, we need handle the situation of
qemu terminated by SIGTERM, otherwise we will get ERROR message in such
case.

Besides, we have a problem that after running qemu, the terminal's behavior
is incorrect regarding long lines or long commands. Long commands or long
outputs should appear in multiple lines, but they appear in the same line,
overriding previous output. Use `tput smam' to fix this problem.

Signed-off-by: Chen Qi <[email protected]>
---
  scripts/runqemu | 14 ++++++++++----
  1 file changed, 10 insertions(+), 4 deletions(-)

diff --git a/scripts/runqemu b/scripts/runqemu
index 409d17c..bc2aba5 100755
--- a/scripts/runqemu
+++ b/scripts/runqemu
@@ -1213,9 +1213,12 @@ class BaseConfig(object):
          cmd = "%s %s" % (self.qemu_opt, kernel_opts)
          logger.info('Running %s\n' % cmd)
          process = subprocess.Popen(cmd, shell=True, stderr=subprocess.PIPE)
-        self.qemupid = process.pid
-        if process.wait():
-            logger.error("Failed to run qemu: %s", 
process.stderr.read().decode())
+        retcode = process.wait()
+        if retcode:
+            if retcode == -signal.SIGTERM:
+                logger.info("Qemu terminated by SIGTERM")
+            else:
+                logger.error("Failed to run qemu: %s", 
process.stderr.read().decode())

      def cleanup(self):
          if self.cleaned:
@@ -1308,8 +1311,10 @@ def main():

          def sigterm_handler(signum, frame):
              logger.info("SIGTERM received")
-            os.kill(config.qemupid, signal.SIGTERM)
+            signal.signal(signal.SIGTERM, signal.SIG_IGN)
+            os.kill(0, signal.SIGTERM)
              config.cleanup()
+            subprocess.run(["tput", "smam"])
          signal.signal(signal.SIGTERM, sigterm_handler)

          config.check_args()
@@ -1331,6 +1336,7 @@ def main():
          return 1
      finally:
          config.cleanup()
+        subprocess.run(["tput", "smam"])

  if __name__ == "__main__":
      sys.exit(main())
--
1.9.1

--
_______________________________________________
Openembedded-core mailing list
[email protected]
http://lists.openembedded.org/mailman/listinfo/openembedded-core


--
_______________________________________________
Openembedded-core mailing list
[email protected]
http://lists.openembedded.org/mailman/listinfo/openembedded-core

Reply via email to