The qemu shutdown can race with the signal handler removal leading to
confusing tracebacks on slower/loaded systems.

Remove the signal handler first before shutting down.

Signed-off-by: Richard Purdie <[email protected]>
---
 meta/lib/oeqa/utils/qemurunner.py | 4 ++--
 1 file changed, 2 insertions(+), 2 deletions(-)

diff --git a/meta/lib/oeqa/utils/qemurunner.py 
b/meta/lib/oeqa/utils/qemurunner.py
index c3c643d7107..dfab1bd5f11 100644
--- a/meta/lib/oeqa/utils/qemurunner.py
+++ b/meta/lib/oeqa/utils/qemurunner.py
@@ -350,10 +350,10 @@ class QemuRunner:
         return True
 
     def stop(self):
-        self.stop_thread()
-        self.stop_qemu_system()
         if hasattr(self, "origchldhandler"):
             signal.signal(signal.SIGCHLD, self.origchldhandler)
+        self.stop_thread()
+        self.stop_qemu_system()
         if self.runqemu:
             if hasattr(self, "monitorpid"):
                 os.kill(self.monitorpid, signal.SIGKILL)
-- 