On a loaded builder we've seen the log message not make it to the log file before the ssh command completes. Add a short delay to try and ensure this does happen. There is unforunately no way to flush syslog in all cases we test.
Signed-off-by: Richard Purdie <[email protected]> --- meta/lib/oeqa/runtime/cases/oe_syslog.py | 3 +++ 1 file changed, 3 insertions(+) diff --git a/meta/lib/oeqa/runtime/cases/oe_syslog.py b/meta/lib/oeqa/runtime/cases/oe_syslog.py index 449df233d13..3a8271a53a8 100644 --- a/meta/lib/oeqa/runtime/cases/oe_syslog.py +++ b/meta/lib/oeqa/runtime/cases/oe_syslog.py @@ -85,6 +85,9 @@ class SyslogTestConfig(OERuntimeTestCase): msg = "Can't log into syslog. Output: %s " % output self.assertEqual(status, 0, msg=msg) + # There is no way to flush the logger to disk in all cases + time.sleep(1) + status, output = self.target.run('grep foobar /var/log/messages') if status != 0: if self.tc.td.get("VIRTUAL-RUNTIME_init_manager") == "systemd": -- 2.20.1 -- _______________________________________________ Openembedded-core mailing list [email protected] http://lists.openembedded.org/mailman/listinfo/openembedded-core