Old versions of ldd (2.11) as run on some of the autobuilders end up running commands like "LD_xxxx qemu-system-xxx" which this process detection code would pick up and result in the wrong PID for qemu.
This changes the code to check for "192.168" in the command so we know we're getting the correct one. This is less than ideal however we're running out of options and resolves false negatives we see on the autobuilder. Signed-off-by: Richard Purdie <[email protected]> --- diff --git a/scripts/qemuimage-testlib-pythonhelper b/scripts/qemuimage-testlib-pythonhelper index 4e6432b..6435dd8 100755 --- a/scripts/qemuimage-testlib-pythonhelper +++ b/scripts/qemuimage-testlib-pythonhelper @@ -54,9 +54,10 @@ if options.findqemu: #print "Children matching %s:" % str(parents) for p in parents: # Need to be careful here since runqemu-internal runs "ldd qemu-system-xxxx" + # Also, old versions of ldd (2.11) run "LD_XXXX qemu-system-xxxx" basecmd = commands[p].split()[0] basecmd = os.path.basename(basecmd) - if "qemu-system" in basecmd: + if "qemu-system" in basecmd and "192.168" in commands[p]: print p sys.exit(0) sys.exit(1) _______________________________________________ Openembedded-core mailing list [email protected] http://lists.linuxtogo.org/cgi-bin/mailman/listinfo/openembedded-core