Hi, All

Supporse two Flowspace rules exists in flowvisor:


Rule1: dpid=9 x=1, y=2, z=3, priority=10 Slice:Bob=4
Rule2: dpid=9 x=1, y=2          priority=1   Slice:Alice=4


In which x,y and z are three different match fields, Now a Packet_In message 
with x=1,y=2,z=4 comes, FlowVisor will direct it to Alice's controller, 
furthermore, Alice's controller send a FlowMod message not specifying field z 
and install a FlowEntry in switch(dpid=9). Once a new flow with x=1,y=2,z=3 
which should belongs to Bob comes, the switch will forward it according to the 
previously installed flowentry(x=1,y=2,z=*), i.e. Slice Alice controls flows of 
slice Bob, so How to implement flow isolation in this situation?


Thanks.