On 9/23/13 5:42 PM, Ming-Chen Zhao wrote:

I am wondering if there are any papers or documents mentioned the
measurement data about flow setup rate in production network.

I'm not sure whether you're asking about the maximum possible flow setup rate or the observed flow setup rate. The observed flow setup rate will depend on what the controller is doing; for example a network with proactive destination-based forwarding would have almost no flow setups. Until a switch fails and there will be a burst of 1,000 flow mods per second.

--